Performance System
Control/AmplificationMilbank mixer amplifier (Usually operated from the stage but can be operated from the control room)
SpeakersMilbank column speakers (2)
Ancillary EquipmentCassette decks (1)
Compact disc(1)
Microphones - Shure SM58 (3)
Assorted microphone stands
Communications
 There are no headset, show relay or paging systems installed
Systems for the Hearing Impaired
 There is an Induction loop installed in the main auditorium for the hearing impaired, there is also an induction loop installed in the Green Room.
Stage Lighting
Power Supply (to stage lighting)3 Phase 60 amps per phase
Dimmers3 Strand Perma (12) racks (36 @2Kw circuits, all hard wired)
ControlStrand Tempus 36 2G manual board
(Operated from the control room at the rear of the hall or stage left)
Lanterns (All lanterns are from the Strand range, all lanterns are rigged)
Harmony 22/40 4 Patt 60 (4)
Harmony PC 4 Patt 137 (4)
Patt 23 10 S63 battern (8)
Patt 833 (12)
Solo 2kw followspots (2)
Additional Power Supplies Available
 There are no additional 3 phase power supplies.
Stage
Dimensions
The stage is flat and is surfaced with varnished tong and grove wood planks.
Proscenium opening - 9.14m x 3.65m,
Maximum stage depth - 7.16m
Stage height - 1.16m
Grid height – 4.87m
Wings maximum – 3.5m
Drapes/Masking
The masking legs and borders are black. There are also two pairs of black tabs and a white cyclorama.
The house tabs (hand winch operated from stage left) and house border are blue in colour.
Flying FacilitiesThere is one hemp set at the rear of the stage; this usually has the cyclorama on it.
There are 2 wipe tracks which can be used to hang cloths on but there is no height for flying.