| Performance System | |
| There is a new (November 2003) sound system installed in the auditorium, a new control position has been created at the rear of the balcony. | |
| Control | Allan and Heath GL2200 24:4:2 |
| Speakers | Logic Systems 1 Pair LS15 (main) 1 Pair LS12 (balcony delays) 1 Pair IS7 (stalls delay) 3 IS6 (front stalls infill) 1 Pair 15 (sub bass) 1 Pair CM12 (foldback) |
| Amplification | Work SP2800, SP1600 and SP950 |
| Ancillary Equipment | BSS Sound Web (delays & processing) BSS FCS 966 dual graphics (2) Phonic DFX256 effects Tascam MD350 mini disc player Tascam CD160 Compact disc player Tascam 202 Mkiii Cassette deck Microphones - Shure SM58 (5), Shure BG 2.1 (1) AKG C451/CK8 (6), Sennheiser hand held radio microphone EMO D.I, boxes (2) |
| Paging | There is a custom built paging system to a number of zones, this can be done from the box office (located off the main foyer), the control room and the stage managers desk (limited call zones from this location) |
| Communications | |
| Headset Communications | Areac custom built system with a master control. (i.e. no individual control). There are 13 outlets around the stage and auditorium. |
| Headsets | Beyer DT108 single sided headsets (8) Beyer DT109 double sided headsets (2) |
| Show Relay | Custom built Areac system to the dressing rooms props area (stage right) and foyer, with a paging facility from the control room and the stage managers desk (stage left). |
| Stage Lighting | |
| Power Supply | 3 Phase 100 amps per phase |
| Dimmers | 2 Strand Permus 24 (24@ 2.5Kw per circuit) |
| Control | Strand MX48 (this is operated from the rear of the balcony) There is also a Zero88 Jester down stage left which can be used for focusing or running the show from side of stage |
| Lanterns (These are all rigged) | Harmony 15/28 (18) Harmony F (24) PAR 64 (10) Coda 3 (8) Solo CSI followspots (2) |
| Addtional Power Supplies Available | |
There is a 3 phase 125amp per phase supply available stage left; this is fitted with a CEE Form 125amp socket outlet. In addition there is a single phase 32amp supply available under the stage for additional sound equipment, this is also fitted with a CEE Form single phase 32amp socket outlet. These supplies are in addition to the ring main available on stage. Note – All power supplies are protected by 30mA RCD protection. | |
| Stage Facilities | |
| Dimensions | The stage is raked and surfaced with boarding sheets, the stage floor is painted black. Proscenium opening - 9.14m x 4.88m, Maximum stage depth - 9.14m Stage height - 1.18m Grid height – 9.14m Wings maximum – 0.9m Stage width (minus wings) = 8.40m |
| Drapes/Masking | The house tabs legs and border are wine red in colour, the house tabs are electrically operated from stage left, there are a pair of grey tabs mid-stage and a pair of black tabs upstage with an off white cyclorama just behind the black tabs. Both pairs of tabs are hand operated, (stage left). There are 4 black borders and 4 pairs of black legs which make up the remaining masking. |
| Flying Facilities | There is hemp flying from a gallery stage left, there are a total of 16 hemp sets in place each with a maximum safe working load of 150Kg however 11 of these are used to fly the above legs, borders, cyclorama etc. There is a total grid safe working load of 1 Ton (1.02 Tonnes), the existing bars and lanterns account for approximately 480Kg, (this excludes the weight of the drapes which are hanging). |
| Audio Visual Equipment | |
| Projectors | Kodak slide projectors (2) Bell and Howell overhead projector (1) |
| Screens | 6ft square (2) |